Abstract
A method of determining the minimum amount of oxygen in the flue gas which results in the most efficient combustion is discussed. Results of field test are presented. The magnitude of the stack gas losses is dependent on the stack gas composition determined by the fuel and quantity of excess air and the stack temperature.
Recommended Citation
Maples, Dupree and Whitehouse, G. D., "Industrial Energy Conservation through Boiler Operation Efficiency Improvement" (1978). UMR-MEC Conference on Energy / UMR-DNR Conference on Energy. 420, pp. 547-553.
https://scholarsmine.mst.edu/umr-mec/420
Meeting Name
5th Annual UMR-DNR Conference on Energy (1978: Oct. 10-12, Rolla, MO)
Document Type
Article - Conference proceedings
Session
Industrial Energy Conservation I
Document Version
Final Version
File Type
text
Language(s)
English
Rights
© 1978 University of Missouri--Rolla, All rights reserved.
Publication Date
12 Oct 1978