In this paper a total of 36 stub columns was tested by two different experimental procedures, namely the FEM and AISI procedures, to investigate the difference in the ultimate load between these procedures. Of these 26 were carried out in the pin-ended condition according to FEM, the rest were in the fixed-end condition according to AlSI specification. It is shown that the failure loads obtained by the two experimental procedures were very close to each other. Both procedures worked well. The AISI procedure is recommended as the standard procedure.

Department(s)

Civil, Architectural and Environmental Engineering

Research Center/Lab(s)

Wei-Wen Yu Center for Cold-Formed Steel Structures

Meeting Name

14th International Specialty Conference on Cold-Formed Steel Structures

Publisher

University of Missouri--Rolla

Document Version

Final Version

Rights

© 1998 University of Missouri--Rolla, All rights reserved.

Document Type

Article - Conference proceedings

File Type

text

Language

English

Share

 
COinS
 
Oct 15th, 12:00 AM

Experimental Procedures for Stub Column Tests

In this paper a total of 36 stub columns was tested by two different experimental procedures, namely the FEM and AISI procedures, to investigate the difference in the ultimate load between these procedures. Of these 26 were carried out in the pin-ended condition according to FEM, the rest were in the fixed-end condition according to AlSI specification. It is shown that the failure loads obtained by the two experimental procedures were very close to each other. Both procedures worked well. The AISI procedure is recommended as the standard procedure.