Effect of Time Delay Skew on Differential Insertion Loss in Weak and Strong Coupled PCB Traces
Abstract
In this paper, effect of time delay skew (TDS) on differential insertion loss (IL) is studied in both weak and strong forward coupling cases. It is showed that TDS impacts differential IL and impact depends on amount of forward coupling. To predict additional differential IL due to TDS, analytical formula is derived and heuristic formula is constructed based on fitting to simulation results in weak and strong forward coupling cases, respectively. The predictions are validated by simulations and measurements.
Recommended Citation
D. Nozadze et al., "Effect of Time Delay Skew on Differential Insertion Loss in Weak and Strong Coupled PCB Traces," Proceedings of the 2017 IEEE 26th Conference on Electrical Performance of Electronic Packaging and Systems (2017, San Jose, CA), pp. 1 - 3, Institute of Electrical and Electronics Engineers (IEEE), Jan 2018.
The definitive version is available at https://doi.org/10.1109/EPEPS.2017.8329757
Meeting Name
26th IEEE Conference on Electrical Performance of Electronic Packaging and Systems, EPEPS 2017 (2017: Oct. 15-18, San Jose, CA)
Department(s)
Electrical and Computer Engineering
Research Center/Lab(s)
Electromagnetic Compatibility (EMC) Laboratory
Keywords and Phrases
Glass Weave; High-Speed Digital Signal; PCB Material; Skew
International Standard Book Number (ISBN)
978-146736483-6
Document Type
Article - Conference proceedings
Document Version
Citation
File Type
text
Language(s)
English
Rights
© 2018 Institute of Electrical and Electronics Engineers (IEEE), All rights reserved.
Publication Date
18 Jan 2018