Abstract

Pressure drop measurements were made on a variety of dilute solid‐liquid suspension systems in order to study the effects of particle shape and size, concentration, fluid viscosity, and tube diameter on friction factor. The central objective was to determine under what conditions drag reduction would occur. Copyright © 1975 American Institute of Chemical Engineers