Location
Rolla, Missouri
Session Dates
11 Jun 1999 - 17 Jun 1999
Keywords and Phrases
Fans; Centrifugal; Axial; Shaft Alignment; Vibration; Testing; Commissioning
Abstract
This study summarizes the technical aspects related to the installation of two main fans at P.T. Freeport Indonesia: one centrifugal and one axial. The fans were installed to increase the exhaust capacity of two vent systems. The 450 kW fan has been installed on surface to support an underground mine expansion project. The installation included the construction of a transition chamber, a retention wall, and the fan installation and commissioning. The 250 kW fan has been installed in an incline to increase the exhaust capacity of an ore pass ventilation system. The study presents the installation details from ground excavation and civil constructions to the fan installation and commissioning. It also includes the results of fan tests.
Department(s)
Mining Engineering
Meeting Name
8th U.S. Mine Ventilation Symposium
Publisher
University of Missouri--Rolla
Document Version
Final Version
Document Type
Article - Conference proceedings
File Type
text
Language
English
Recommended Citation
Calizaya, Felipe and Mulyadi, A., "Installation of Two Main Fans at P.T. Freeport Indonesia's Underground Facilities" (1999). U.S. Mine Ventilation Symposium. 1.
https://scholarsmine.mst.edu/usmvs/8usmvs/8usmvs-theme13/1
Installation of Two Main Fans at P.T. Freeport Indonesia's Underground Facilities
Rolla, Missouri
This study summarizes the technical aspects related to the installation of two main fans at P.T. Freeport Indonesia: one centrifugal and one axial. The fans were installed to increase the exhaust capacity of two vent systems. The 450 kW fan has been installed on surface to support an underground mine expansion project. The installation included the construction of a transition chamber, a retention wall, and the fan installation and commissioning. The 250 kW fan has been installed in an incline to increase the exhaust capacity of an ore pass ventilation system. The study presents the installation details from ground excavation and civil constructions to the fan installation and commissioning. It also includes the results of fan tests.