Abstract
The one square kilometer array (KM2A), a sub-array of Large High Altitude Air Shower Observatory (LHAASO) experiment, consists of 5195 electromagnetic particle detectors (EDs) and 1188 muon detectors (MDs), has been built over three-quarters scale. Its main scientific goal is to search gamma-ray sources at energies above 100 TeV. Offline calibration method has been used to calibrate thousands of EDs to guarantee the key performances of the array such as angular resolution and pointing accuracy within 0.1° during long-term operation. The experimental results of the 3/4 array show that this method can be used to determine the detector time offset with an accuracy of 0.5 ns and the particle number density with an accuracy of a few percent. Furthermore, we monitor the calibration parameters during the array operation and update the calibration results regularly to ensure the data quality of the detector.
Recommended Citation
"Time And Charge Calibration Of The LHAASO Electromagnetic Particle Detectors," Proceedings of Science, vol. 395, article no. 740, Sissa Medialab Srl, Mar 2022.
The definitive version is available at https://doi.org/10.22323/1.395.0740
Department(s)
Physics
Publication Status
Open Access
International Standard Serial Number (ISSN)
1824-8039
Document Type
Article - Conference proceedings
Document Version
Citation
File Type
text
Language(s)
English
Rights
© 2025 Sissa Medialab Srl, All rights reserved.
Publication Date
18 Mar 2022

Comments
National Natural Science Foundation of China, Grant 11947404