Performance Analysis of a Neutron and X-Ray Combined Computed Tomography System
Abstract
A novel neutron and X-ray combined computed tomography system (NXCT) has been developed at the Missouri University of Science & Technology. It is believed that it will provide a superior method for non-destructive testing and evaluation. The system is housed within the Missouri University of Science & Technology Reactor (MSTR) and is the first such imaging platform and synthesis method to be developed. The system utilizes neutrons obtained directly from the reactor core and X-rays from an X-ray generator. Characterization of the newly developed digital imaging system is imperative to the performance evaluation, as well as for describing the associated parameters. The preliminary evaluation of the NXCT system was performed in terms of image uniformity, linearity and spatial resolution. Additionally, the correlation between the applied beam intensity, the resulting image quality, and the system sensitivity was investigated. The combined neutron/X-ray digital imaging system was evaluated in terms of performance parameters and results are detailed. The Modulation Transfer Function (MTF) of the X-ray imaging module was calculated using the Edge method. The spatial frequency at 10% of the MTF was found to be 8 l p/mm, which is in agreement with the value of 8.5 l p/mm determined from the square wave response method. The highest detective quantum efficiency of the X-ray imaging module was found to be 0.53. Furthermore, the Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE) spectrum for the neutron imaging module was also evaluated in a similar way as the X-ray imaging module. In order to improve the image quality of the neutron imaging module, a pin-hole mask phantom was used to correct the geometrical non-linearity of the delay line anode readout. The non-linearity correction of the delay line anode readout has been shown through the corrected images of perforated cadmium strip and electroformed phantom.
Recommended Citation
V. Sinha et al., "Performance Analysis of a Neutron and X-Ray Combined Computed Tomography System," Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Elsevier, Jan 2014.
The definitive version is available at https://doi.org/10.1016/j.nima.2014.03.004
Department(s)
Nuclear Engineering and Radiation Science
Keywords and Phrases
Modulation Transfer Function; Noise Power Spectrum; Detective Quantum Efficiency; Neutron Detector; X-Ray Detector
International Standard Serial Number (ISSN)
0168-9002
Document Type
Article - Journal
Document Version
Citation
File Type
text
Language(s)
English
Rights
© 2014 Elsevier, All rights reserved.
Publication Date
01 Jan 2014