Optimized Canopy Air Curtain Dust Protection using a Two-Level Manifold and Computational Fluid Dynamics
Abstract
Prolonged exposure to high concentrations of respirable coal mine dust causes coal workers' pneumoconiosis and silicosis. Underground coal mine roof bolter operators are more prone to elevated exposure to coal and silica dust. The canopy air curtain (CAC) was developed by NIOSH to protect roof bolter operators from the exposure. The CAC supplies filtered air over the breathing zone of the operator. This dilutes the high coal dust concentrations and provides for an impenetrable air curtain. Many studies have been carried out to improve CAC efficiency. However, field test has shown variable dust control efficiencies indicating room for further improvement due to the non-uniform airflow distribution across the plenum and ineffective perimeter flow. This study therefore redesigns the CAC with optimized flow distribution that effectively protects roof bolters from coal dust exposures. The Simplex Evolutionary Operational (EVOP) optimization algorithm was applied to optimize the configuration of the new CAC. Computational fluid dynamics (CFD) simulations are run at each iteration of the algorithm. The combination of these methodologies led to the optimization of the uniformity of airflow distribution across the plenum to achieve the best possible uniformity. A lab experiment using a physical model of the optimized CAC was used to validate the CFD model and confirm the ability of this design to protect roof bolter operators from excessive coal dust.
Recommended Citation
N. A. Amoah et al., "Optimized Canopy Air Curtain Dust Protection using a Two-Level Manifold and Computational Fluid Dynamics," Mining, Metallurgy and Exploration, vol. 41, no. 4, pp. 1807 - 1818, Springer, Aug 2024.
The definitive version is available at https://doi.org/10.1007/s42461-024-01021-2
Department(s)
Mining Engineering
Keywords and Phrases
Canopy air curtain (CAC); Coal mine dust; Coal workers' pneumoconiosis; Computational fluid dynamics (CFD); Dust Control
International Standard Serial Number (ISSN)
2524-3470; 2524-3462
Document Type
Article - Journal
Document Version
Citation
File Type
text
Language(s)
English
Rights
© 2024 Springer, All rights reserved.
Publication Date
01 Aug 2024