Abstract
A study has been made of the application of impact dampers to two types of continuous systems, a simply supported and a clamped beam. Experimental models were tested in the laboratory and computer programs were developed to calculate response by two separate approaches. Results from calculations agreed favorably with experimental tests. Curves presented show the response to be expected for values of significant system parameters and enable the user to apply impact dampers to these types of continuous systems. © 1975 by ASME.
Recommended Citation
R. K. Roy et al., "The Application Of Impact Dampers To Continuous Systems," Journal of Manufacturing Science and Engineering, Transactions of the ASME, vol. 97, no. 4, pp. 1317 - 1324, American Society of Mechanical Engineers, Jan 1975.
The definitive version is available at https://doi.org/10.1115/1.3438755