Role of Water Temperature in Case of High Mass Flux Spray Cooling of a Hot AISI 304 Steel Plate at Different Initial Surface Temperatures

Abstract

In case of spray evaporative cooling, the heat transfer rate is controlled by various factors such as droplet renewal rate, Leidenfrost effect, and the rate of heat extraction by each droplet. In the current work, in case of high mass flux spray cooling (~55 kg/m2s), the heat extraction rate is tried to enhance by increasing the water temperature. Furthermore, from different initial surface temperatures (300°C-800°C), cooling experiments were conducted at various water temperatures (10°C-50°C). The surface temperatures and heat fluxes are calculated using an inverse heat conduction software (INTEMP). The result reveals that with the increasing water temperature, the heat removal rate rises in both transition and nucleate boiling regimes due to the increment of latent heat extraction time during the residence period of the water droplet on the hot plate. The maximum percentage in the enhancement of initial heat flux, average heat flux (AHF), and critical heat flux (CHF) are achieved in the nucleate boiling regime ( < 600°C); however, the increment in the transition boiling regime is also significant.

Department(s)

Materials Science and Engineering

Keywords and Phrases

drop renewal; latent heat; nucleate boiling; sensible heat; Spray cooling; subcooling; transition boiling

International Standard Serial Number (ISSN)

0891-6152;1521-0480

Document Type

Article - Journal

Document Version

Citation

File Type

text

Language(s)

English

Rights

© 2017 Taylor & Francis Ltd., All rights reserved.

Publication Date

01 Sep 2017

Share

 