Masters Theses

Keywords and Phrases

Tridiagonal matrix inverse

Abstract

"Transient response of a natural convection system is investigated by numerical simulation using FLUENT code. An Integrator Circuit analogy was recently proposed for natural convection system. The proposed analogy was further confirmed by these recent simulations. New simulation results also suggest that a natural convection system acts as a "Low Pass" filter for transients. Transient transmission/attenuation factor was found to be a function of both fluid properties and the flow characteristics. Transmission/attenuation factor was also found to be a strong function of fluctuation frequency"--Abstract, page iv.

Advisor(s)

Usman, Shoaib

Committee Member(s)

Mueller, Gary Edward, 1954-
Kim, S.

Department(s)

Nuclear Engineering and Radiation Science

Degree Name

M.S. in Nuclear Engineering

Publisher

University of Missouri--Rolla

Publication Date

Summer 2007

Journal article titles appearing in thesis/dissertation

  • Explicit inversion formulas for tridiagonal matrices
  • Natural convection's transient behavior

Pagination

viii, 35 pages

Rights

© 2007 Bassam Sabry Mohammad Abdelnabi, All rights reserved.

Document Type

Thesis - Open Access

File Type

text

Language

English

Subject Headings

Electric filters, Resistance-capacitanceHeat -- ConductionHeat -- ConvectionTransients (Dynamics)

Thesis Number

T 9126

Print OCLC #

173282122

Electronic OCLC #

181160855

Share

 
COinS