"The average electron density and electron confinement time in an electrostatically plugged magnetic spindle cusp device are studied using a 20 GHz microwave interferometer. The results are compared with the predictions from approximate theoretical equations. With a magnetic induction in the point cusp of 5000 Gauss, a plasma is produced by injecting a 5 mA, 500 eV electron beam into hydrogen gas at 10-5 Torr. The measured electron density is 2 x 10-10 cm-3 and the measured confinement time is 80 ysec, which agree to within a factor of two with values predicted by theory"--Abstract, page ii.