Session Dates

07 Nov 2018 - 08 Nov 2018

Abstract

In this paper, the strength and stiffness of different roof panels were investigated, in order to establish their ability to act as in-plane diaphragms for stressed skin design of cold-formed steel portal frames. A total of 6 roof panels, approximately 3 x 3m, were examined by testing with sheeting profiles fixed on 4 sides. A variety of sheeting profiles in two industry standard thicknesses of 0.5 and 0.7mm were tested, all using top-hat shaped purlins fixed with self-drilling, self-tapping screws. The experimental strength and stiffness of each panel were then compared against existing design methods. The Finite Element Analysis (FEA) modelling techniques were also presented and validated against series of full-scale tests. The FEA results have shown that the ‘true’ level of loading transferred via shear connector screws was on average 13% lower than that assumed by standard design methods. On the contrary, seam connections failure, according to FEA results, have governed a design in all of the analysed cases and the analytical method overestimated shear resistances of the panels by 45% and 35% in case of 0.5mm and 0.7mm thick sheeting profiles respectively. It was demonstrated that FEA results have represented the upper bound of experimental shear stiffness, with a very close prediction for 0.5mm thick sheeting profiles. Overall all, the tested panels demonstrated an average 41% greater flexibility then this predicted using FEA models.

Department(s)

Civil, Architectural and Environmental Engineering

Meeting Name

Wei-Wen Yu International Specialty Conference on Cold-Formed Steel Structures 2018

Publisher

Missouri University of Science and Technology

Document Version

Final Version

Rights

© 2018 Missouri University of Science and Technology, All rights reserved.

Document Type

Article - Conference proceedings

File Type

text

Language

English

Share

 
COinS
 
Nov 7th, 12:00 AM Nov 8th, 12:00 AM

Stressed Skin Design of Steel Sheeting Panels – Part 2: Shear Panels with Sheeting Fixed on all 4 Sides

In this paper, the strength and stiffness of different roof panels were investigated, in order to establish their ability to act as in-plane diaphragms for stressed skin design of cold-formed steel portal frames. A total of 6 roof panels, approximately 3 x 3m, were examined by testing with sheeting profiles fixed on 4 sides. A variety of sheeting profiles in two industry standard thicknesses of 0.5 and 0.7mm were tested, all using top-hat shaped purlins fixed with self-drilling, self-tapping screws. The experimental strength and stiffness of each panel were then compared against existing design methods. The Finite Element Analysis (FEA) modelling techniques were also presented and validated against series of full-scale tests. The FEA results have shown that the ‘true’ level of loading transferred via shear connector screws was on average 13% lower than that assumed by standard design methods. On the contrary, seam connections failure, according to FEA results, have governed a design in all of the analysed cases and the analytical method overestimated shear resistances of the panels by 45% and 35% in case of 0.5mm and 0.7mm thick sheeting profiles respectively. It was demonstrated that FEA results have represented the upper bound of experimental shear stiffness, with a very close prediction for 0.5mm thick sheeting profiles. Overall all, the tested panels demonstrated an average 41% greater flexibility then this predicted using FEA models.