Session Dates

10 Nov 2016

Abstract

This paper examines the accuracy of design equations specified in the North American and European codes for cold-formed steel structures in determining the ultimate tilt bearing capacity of single-shear single-row bolted connections without washers in flat steel sheets. It points out that the code equations do not properly distinguish the tilt bearing failure mode from the conventional bearing failure mode, which is typical of double-shear connections and single-shear connections with washers. The tilt bearing capacity is affected by the width of the connected sheet, and its capacity does not vary linearly with either the sheet thickness or the bolt diameter. Based on the test results of 150 specimens composed of G2 and G450 sheet steels having various dimensional configurations, this paper proposes a design equation that is dimensionally consistent and that is considerably more accurate than all the code equations. The proposed equation was also verified against single-shear single-row bolted connections tested by independent researchers which failed in the tilt bearing mode. A resistance factor of 0.75 is recommended for use with the proposed equation for determining the ultimate tilt bearing capacity of single shear single-row bolted connections in cold-reduced steel sheets.

Department(s)

Civil, Architectural and Environmental Engineering

Research Center/Lab(s)

Wei-Wen Yu Center for Cold-Formed Steel Structures

Meeting Name

International Specialty Conference on Cold-Formed Steel Structures 2016

Publisher

Missouri University of Science and Technology

Document Version

Final Version

Rights

© 2016 Missouri University of Science and Technology, All rights reserved.

Document Type

Article - Conference proceedings

File Type

text

Language

English

Share

 
COinS
 
Nov 10th, 12:00 AM Nov 10th, 12:00 AM

Tilt Bearing Capacity of Single-Shear Bolted Connections without Washers

This paper examines the accuracy of design equations specified in the North American and European codes for cold-formed steel structures in determining the ultimate tilt bearing capacity of single-shear single-row bolted connections without washers in flat steel sheets. It points out that the code equations do not properly distinguish the tilt bearing failure mode from the conventional bearing failure mode, which is typical of double-shear connections and single-shear connections with washers. The tilt bearing capacity is affected by the width of the connected sheet, and its capacity does not vary linearly with either the sheet thickness or the bolt diameter. Based on the test results of 150 specimens composed of G2 and G450 sheet steels having various dimensional configurations, this paper proposes a design equation that is dimensionally consistent and that is considerably more accurate than all the code equations. The proposed equation was also verified against single-shear single-row bolted connections tested by independent researchers which failed in the tilt bearing mode. A resistance factor of 0.75 is recommended for use with the proposed equation for determining the ultimate tilt bearing capacity of single shear single-row bolted connections in cold-reduced steel sheets.