Session Dates
06 Nov 2014
Abstract
Shear wall panels are commonly used as lateral load resisting elements to provide stability of the cold-formed steel-framed houses in Australia against wind and earthquake actions. The effectiveness of their lateral resistance behavior is obtained usually by experimental testing although it can also be done by analytical modeling. This paper presents racking test results of steelframed wall panels with different aspect ratios sheathed with fibre cement board subjected to monotonic and cyclic loading protocol. Performance parameters of the wall panels are obtained from the experimentally observed load-deflection curves using various existing methods and evaluation method is proposed. The evaluation method considers various performance characteristics including ductility modification factor, residual displacement recovery and load levels satisfying ultimate and serviceability limit state conditions.
Department(s)
Civil, Architectural and Environmental Engineering
Research Center/Lab(s)
Wei-Wen Yu Center for Cold-Formed Steel Structures
Sponsor(s)
ARC Linkage Project
National Association of Steel-framed Housing
Meeting Name
22nd International Specialty Conference on Cold-Formed Steel Structures
Publisher
Missouri University of Science and Technology
Document Version
Final Version
Rights
© 2014 Missouri University of Science and Technology, All rights reserved.
Document Type
Article - Conference proceedings
File Type
text
Language
English
Recommended Citation
Shahi, Rojit; Lam, Nelson; Gad, Emad; Saifullah, Ismail; Wilson, John; and Watson, Ken, "In-Plane Behavior of Cold-Formed Steel-Framed Shear Wall Panels Sheathed with Fibre Cement Board" (2014). CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018). 3.
https://scholarsmine.mst.edu/isccss/22iccfss/session11/3
In-Plane Behavior of Cold-Formed Steel-Framed Shear Wall Panels Sheathed with Fibre Cement Board
Shear wall panels are commonly used as lateral load resisting elements to provide stability of the cold-formed steel-framed houses in Australia against wind and earthquake actions. The effectiveness of their lateral resistance behavior is obtained usually by experimental testing although it can also be done by analytical modeling. This paper presents racking test results of steelframed wall panels with different aspect ratios sheathed with fibre cement board subjected to monotonic and cyclic loading protocol. Performance parameters of the wall panels are obtained from the experimentally observed load-deflection curves using various existing methods and evaluation method is proposed. The evaluation method considers various performance characteristics including ductility modification factor, residual displacement recovery and load levels satisfying ultimate and serviceability limit state conditions.
Comments