An Analog Implementation Of The Constant Statistics Constraint For Sensor Calibration
Abstract
We use the constant statistics constraint to calibrate an array of sensors that contains gain and offset variations. This algorithm has been mapped to analog hardware and designed and fabricated with a 2um CMOS technology. Measured results from the chip show that the system achieves mvariance to gain and offset variations of the input signal.
Recommended Citation
J. G. Harris and Y. M. Chiang, "An Analog Implementation Of The Constant Statistics Constraint For Sensor Calibration," Advances in Neural Information Processing Systems, pp. 699 - 705, Neural Information Processing Systems Foundation, Jan 1997.
Department(s)
Electrical and Computer Engineering
International Standard Book Number (ISBN)
978-026210065-6
International Standard Serial Number (ISSN)
1049-5258
Document Type
Article - Conference proceedings
Document Version
Citation
File Type
text
Language(s)
English
Rights
© 2025 Neural Information Processing Systems Foundation, All rights reserved.
Publication Date
01 Jan 1997