Abstract
The Radiated Emission (RE) Potential Limit Line for Router System is Analyzed from 10 GHz to 40 GHz based on CISPR TR 16-4-4 Standard. Statistical Data is Collected for the Limit Line Extraction from Measurement, Numerical Analysis, 3D Full-Wave Simulation and Literature Studies. All the Factors Considered in Limit Line Calculation Are Analyzed for Data Center Equipment Operation. the Result of Extracted Potential Limit Line Shows the Rising Limit Line between 10 GHz and 40 GHz Frequency Band for Potential Future Radiated Emission Limit Line above 40 GHz Targeted for High-Speed Equipment Radiated Emission. This Paper is Not a Standard Document but Provides Insight to the Trend for Future Limit Lines above 40GHz.
Recommended Citation
Z. Peng et al., "Analysis on Extraction of Potential Radiated Emission Limit Line for Data Center Equipment from 10 GHz to 40 GHz," 2023 IEEE Symposium on Electromagnetic Compatibility and Signal/Power Integrity, EMC+SIPI 2023, pp. 602 - 607, Institute of Electrical and Electronics Engineers, Jan 2023.
The definitive version is available at https://doi.org/10.1109/EMCSIPI50001.2023.10241656
Department(s)
Electrical and Computer Engineering
Keywords and Phrases
Data center equipment; High frequency; Limit line; Radiated Emission; Standard
Document Type
Article - Conference proceedings
Document Version
Citation
File Type
text
Language(s)
English
Rights
© 2023 Institute of Electrical and Electronics Engineers, All rights reserved.
Publication Date
01 Jan 2023
Comments
National Science Foundation, Grant IIP-1916535