Abstract
Stray load loss in dc machines is denned as the difference between the actual loss under load and the well-recognized loss. This paper describes a simple, reliable, and direct method of measuring this loss by means of a proposed short-circuit test with a correction factor for uncompensated-type dc machines. It also describes the sources and components of stray load losses as they occur under short-circuit test. Copyright © 1968 by The Institute of Electrical and Electronics Engineers, Inc.
Recommended Citation
K. R. Shah and G. McPherson, "A Direct Method Of Measuring Stray Load Loss In DC Machines," IEEE Transactions on Power Apparatus and Systems, vol. PAS thru 87, no. 11, pp. 1925 - 1931, Institute of Electrical and Electronics Engineers, Jan 1968.
The definitive version is available at https://doi.org/10.1109/TPAS.1968.292014
Department(s)
Electrical and Computer Engineering
International Standard Serial Number (ISSN)
0018-9510
Document Type
Article - Journal
Document Version
Citation
File Type
text
Language(s)
English
Rights
© 2023 Institute of Electrical and Electronics Engineers, All rights reserved.
Publication Date
01 Jan 1968