Abstract
Skin and proximity effects can cause a significant drop in the effective leakage inductance of a transformer when the operating frequency is increased. Although the magnetic image method-based double-2-D model can calculate the low-frequency leakage inductance with sufficient accuracy, it is inherently a frequency-independent model. While Dowell's 1-D model uses frequency-dependent relations to account for both skin and proximity effects, its accuracy is severely affected by the assumed winding geometry. In this paper, a hybrid model is proposed that uses superposition to combine a modified Dowell's model with the double-2-D model. The proposed model is investigated on a variable inductance transformer (VIT)-a partially-filled transformer whose leakage inductance can be varied by moving one of the windings mechanically. The frequency-dependent leakage inductances of the VIT evaluated using the hybrid model are in excellent agreement with the corresponding finite element method (FEM) simulated and experimentally measured values, thereby validating the proposed hybrid model.
Recommended Citation
A. Sharma and J. W. Kimball, "New Hybrid Model for Evaluating the Frequency-Dependent Leakage Inductance of a Variable Inductance Transformer (Vit)," 2022 IEEE Energy Conversion Congress and Exposition, ECCE 2022, Institute of Electrical and Electronics Engineers, Jan 2022.
The definitive version is available at https://doi.org/10.1109/ECCE50734.2022.9947451
Department(s)
Electrical and Computer Engineering
Keywords and Phrases
Double-2-D model; Dowell's 1-D model; hybrid model; leakage inductance; variable inductance transformer
International Standard Book Number (ISBN)
978-172819387-8
Document Type
Article - Conference proceedings
Document Version
Final Version
File Type
text
Language(s)
English
Rights
© 2023 Institute of Electrical and Electronics Engineers, All rights reserved.
Publication Date
01 Jan 2022
Comments
Vehicle Technologies Office, Grant DE-EE0008449