Suppression of Leakage Magnetic Field from a Wireless Power Transfer System using Ferrimagnetic Material and Metallic Shielding

Abstract

This paper describes a method to suppress the leakage magnetic field from a wireless power transfer (WPT) system through the use of a ferrimagnetic material and metallic shielding. To demonstrate the advantages of the coil structure with the ferrimagnetic material and metallic shielding, magnetic field distributions and the electrical performance of three different coil structures are investigated via 3D electromagnetic (EM) field solver and SPICE simulation. Results show that the suggested method considerably reduces the leakage magnetic field in the vicinity of the WPT system without significant loss of electrical performance. The simulation results of the suggested coil structure are experimentally verified with a 100 W-class WPT system for an LED TV.

Meeting Name

2012 IEEE International Symposium on Electromagnetic Compatibility, EMC 2012 (2012: Aug. 5-10, Pittsburgh, PA)

Department(s)

Electrical and Computer Engineering

Keywords and Phrases

Coil Structures; Electrical Performance; Leakage Magnetic Field; Magnetic Field Distribution; SPICE Simulations; Wireless Power Transfer, Computer Simulation; Electromagnetic Compatibility; Shielding; SPICE, Magnetic Fields

International Standard Book Number (ISBN)

978-146732061-0

International Standard Serial Number (ISSN)

1077-4076

Document Type

Article - Conference proceedings

Document Version

Citation

File Type

text

Language(s)

English

Rights

© 2012 Institute of Electrical and Electronics Engineers (IEEE), All rights reserved.

Publication Date

10 Aug 2012

Share

 
COinS