Determination of the Effect of Humidity on the Probability of ESD Failure or Upset in Data Centers
Abstract
The relative rate of electrostatic discharge (ESD)-related failures or upsets is derived for various types of data centers based on different flooring systems and personal footwear. As the estimation of the actual number of ESD-related failures or upsets is impossible, hypothetical scenarios of data centers are considered with the assumption that the operator actions and IT equipment are constant in all these data centers. Then, using industry accepted ESD robustness thresholds, the probabilities of exceeding these thresholds are calculated and compared, which allows us to estimate the relative rate of ESD-related failures or upsets as a function of environmental conditions, flooring types, and footwear. The estimation is based on a welldefined walking pattern which has good repeatability. Due to limitations on performing the well-defined walking pattern for long periods of time and due to the small probability of observing very high voltages, an extrapolation approach is used to determine the probabilities of exceeding ESD robustness levels. Two approaches have been used to obtain the extrapolation functions used to predict higher voltage levels. (1) The extrapolation was performed based on the distribution functions measured in our test, and (2) the extrapolation was performed based on literature data. The literature data predicts higher risk levels, however, in many cases both extrapolations lead to the same conclusions with respect to risk level. Based on the calculated probabilities and different categories of data centers, recommendations regarding the flooring system and footwear control are provided.
Recommended Citation
M. Moradian et al., "Determination of the Effect of Humidity on the Probability of ESD Failure or Upset in Data Centers," Proceedings of the 2014 ASHRAE Annual Conference (2014, Seattle, WA), vol. 120, pp. 25 - 41, American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), Jun 2014.
Meeting Name
2014 ASHRAE Annual Conference (2014: Jun. 28-Jul. 2, Seattle, WA)
Department(s)
Electrical and Computer Engineering
Research Center/Lab(s)
Electromagnetic Compatibility (EMC) Laboratory
Keywords and Phrases
Building materials; Distribution functions; Electrostatic discharge; Extrapolation; Floors; Probability; Environmental conditions; ESD robustness; High voltage; Literature data; Operator action; Relative rates; Voltage levels; Walking pattern; Electrostatic devices
International Standard Book Number (ISBN)
978-193650482-4
Document Type
Article - Conference proceedings
Document Version
Citation
File Type
text
Language(s)
English
Rights
© 2014 American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) , All rights reserved.
Publication Date
01 Jun 2014