Doctoral Dissertations
Abstract
"The characteristic boiling curve for Normal Pentane was determined at 1 atmosphere pressure with particular attention devoted to the transition boiling region. The heat transfer surface was a horizontal, gold-plated, copper disc.
Stability analysis was employed to demonstrate why previous investigators have had only limited success in collecting data in the transition region and to provide a valid basis for equipment designed to operate in this region.
A method of predicting the transition region boiling curve from the nucleate curve and the Liedenfrost point is presented. The method was found to predict the transition boiling of Normal Pentane, Freon 12, Freon 113 and Freon 114"--Abstract, page iii.
Advisor(s)
Park, Efton
Committee Member(s)
Johnson, James W., 1930-2002
Flanigan, V. J.
Gaddy, J. L.
Armaly, B. F. (Bassem F.)
Department(s)
Chemical and Biochemical Engineering
Degree Name
Ph. D. in Chemical Engineering
Sponsor(s)
Shell Oil Company
E.I. du Pont de Nemours & Company
Atlantic Richfield Co.
University of Missouri--Rolla. Department of Chemical Engineering
Publisher
University of Missouri--Rolla
Publication Date
1974
Pagination
vii, 53 pages
Note about bibliography
Includes bibliographical references (pages 46-47).
Rights
© 1974 Ronald Martin Canon, All rights reserved.
Document Type
Dissertation - Open Access
File Type
text
Language
English
Subject Headings
Heat -- Transmission -- Mathematical modelsFilm boilingHeat-transfer media
Thesis Number
T 3025
Print OCLC #
6012929
Electronic OCLC #
942082180
Recommended Citation
Canon, Ronald M., "Transition boiling of normal pentane from a horizontal flat gold surface" (1974). Doctoral Dissertations. 295.
https://scholarsmine.mst.edu/doctoral_dissertations/295
Comments
Electronic access to the full-text of this document is restricted to Missouri S&T users. Print thesis not available at Missouri S&T Library.