Micellar Polymer Encapsulation Of Enzymes

Abstract

Although enzymes are highly efficient and selective catalysts, there have been problems incorporating them into fuel cells. Early enzyme-based fuel cells contained enzymes in solution rather than immobilized on the electrode surface. One problem with utilizing an enzyme in solution is an issue of transport associated with long diffusion lengths between the site of bioelectrocatalysis and the electrode. This issue drastically decreases the theoretical overall power output due to the poor electron conductivity. On the other hand, enzymes immobilized at the electrode surface have eliminated the issue of poor electron conduction due to the close proximity of electron transfer between the electrode and the biocatalyst. Another problem is the inefficient and short-term stability of catalytic activity within the enzyme that is suspended in a free-flowing solution. Enzymes in solutions are only stable for hours to days, whereas immobilized enzymes can be stable for weeks to months and now even years. Over the last decade, there has been substantial research on immobilizing enzymes at electrode surfaces for biofuel cell and sensor applications. The most commonly used techniques are sandwich or wired. Sandwich techniques are powerful and successful for enzyme immobilization; however, the enzyme's optimal activity is not retained due to the physical distress applied by the polymer, limiting its applications as well as the nonuniform distribution of the enzyme, and the diffusion of analyte through the polymer is slowed significantly. Wired techniques have shown to extend the lifetime of an enzyme at the electrode surface; however, this technique is very hard to master due to the specific covalent bonding of enzyme and polymer, which changes the three-dimensional configuration of enzyme and with that decreases the optimal catalytic activity. This chapter details entrapment techniques for immobilizing an enzyme within the pores or pockets of hydrophobically modified micellar polymers, such as Nafion® and chitosan. This strategy has been shown to safely immobilize enzymes at electrode surfaces with shelf and continuous operation lifetime of more than 2 years.

Department(s)

Chemistry

Keywords and Phrases

Biofuel cells; Biosensors; Chitosan; Enzyme encapsulation; Enzyme immobilization; Enzyme stabilization; Micellar polymers; Nafion®

International Standard Serial Number (ISSN)

1940-6029; 1064-3745

Document Type

Article - Journal

Document Version

Citation

File Type

text

Language(s)

English

Rights

© 2026 Springer, All rights reserved.

Publication Date

01 Jan 2026

PubMed ID

42461546

Share

 
COinS