"Axial Strength of Purlins Attached to Standing Seam Roof Panels" by John A. Stolarczyk and James M. Fisher
 

American Iron and Steel Institute (AISI) Specifications, Standards, Manuals and Research Reports (1946 - present)

Alternative Title

Research report RP01-8

Abstract

The purpose of this research was to determine the axial load capacity of Z-purlins with one flange attached to a standing seam roof system. The axial load capacity was determined by developing a relationship between the flexural uplift buckling strength and the axial buckling strength in the Z-purlin. This relationship was investigated using finite element models and by conducting a parametric study. At the conclusion of the parametric study, confirmatory tests were conducted to verify the finite element results. Lastly, a relationship has been provided that relates the axial buckling strength in the Z-purlin to the flexural uplift buckling strength.

Department(s)

Civil, Architectural and Environmental Engineering

Sponsor(s)

American Iron and Steel Institute
Metal Building Manufacturers Association

Research Center/Lab(s)

Wei-Wen Yu Center for Cold-Formed Steel Structures

Publisher

American Iron and Steel Institute

Publication Date

01 May 2001

Document Version

Final Version

Rights

© 2001 American Iron and Steel Institute, All rights reserved.