American Iron and Steel Institute (AISI) Specifications, Standards, Manuals and Research Reports (1946 - present)
Alternative Title
Research report RP01-8
Abstract
The purpose of this research was to determine the axial load capacity of Z-purlins with one flange attached to a standing seam roof system. The axial load capacity was determined by developing a relationship between the flexural uplift buckling strength and the axial buckling strength in the Z-purlin. This relationship was investigated using finite element models and by conducting a parametric study. At the conclusion of the parametric study, confirmatory tests were conducted to verify the finite element results. Lastly, a relationship has been provided that relates the axial buckling strength in the Z-purlin to the flexural uplift buckling strength.
Department(s)
Civil, Architectural and Environmental Engineering
Sponsor(s)
American Iron and Steel Institute
Metal Building Manufacturers Association
Research Center/Lab(s)
Wei-Wen Yu Center for Cold-Formed Steel Structures
Publisher
American Iron and Steel Institute
Publication Date
01 May 2001
Document Version
Final Version
Rights
© 2001 American Iron and Steel Institute, All rights reserved.
Document Type
Technical Report
File Type
text
Language
English
Technical Report Number
Report no. 980531JMF
Recommended Citation
Stolarczyk, John A. and Fisher, James M., "Axial Strength of Purlins Attached to Standing Seam Roof Panels" (2001). American Iron and Steel Institute (AISI) Specifications, Standards, Manuals and Research Reports (1946 - present). 94.
https://scholarsmine.mst.edu/ccfss-aisi-spec/94