Session Dates
17 Oct 1996
Abstract
Results from 57 push-out tests of headed shear studs in cold-formed steel deck are presented. The results are compared to predicted strengths using the American Institute of Steel Construction Load and Resistance Factor Design Specification. The results indicate that the AISC specification does not accurately predict the strength of the shear studs placed in steel deck.
Department(s)
Civil, Architectural and Environmental Engineering
Research Center/Lab(s)
Wei-Wen Yu Center for Cold-Formed Steel Structures
Meeting Name
13th International Specialty Conference on Cold-Formed Steel Structures
Publisher
University of Missouri--Rolla
Document Version
Final Version
Rights
© 1996 University of Missouri--Rolla, All rights reserved.
Document Type
Article - Conference proceedings
File Type
text
Language
English
Recommended Citation
Lyons, John C.; Easterling, Samuel W.; and Murray, Thomas M., "Strength of Headed Shear Studs in Cold-formed Steel Deck" (1996). CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018). 3.
https://scholarsmine.mst.edu/isccss/13iccfss/13iccfss-session6/3
Strength of Headed Shear Studs in Cold-formed Steel Deck
Results from 57 push-out tests of headed shear studs in cold-formed steel deck are presented. The results are compared to predicted strengths using the American Institute of Steel Construction Load and Resistance Factor Design Specification. The results indicate that the AISC specification does not accurately predict the strength of the shear studs placed in steel deck.