Reduced-Parts-count Multilevel Rectifiers

Keith Corzine, Missouri University of Science and Technology
J. R. Baker

This document has been relocated to http://scholarsmine.mst.edu/ele_comeng_facwork/1858

There were 12 downloads as of 28 Jun 2016.

Abstract

Multilevel power converters have gained much attention in recent years due to their high power quality, low switching losses, and high-voltage capability. These advantages make the multilevel converter a candidate topology for the next generation of naval ship prolusion systems. The primary disadvantage of these systems is the large number of semiconductors involved. This paper presents a reduced-parts-count rectifier which is well suited for naval rectifier applications where bidirectional power flow is not required. The proposed converter is analyzed and experimentally verified on an 18-kW four-level rectifier/inverter system.